ONNX reference LpNormalization uses a signed sum for p=1
Permanent archive: Zenodo · 10.5281/zenodo.22728971.
The input [1, -1] becomes [0, 0], while the exact L1-normalized result and ONNX Runtime both return [0.5, -0.5].
Claim under test
ONNX defines LpNormalization as division by an Lp norm along a selected axis. For p=1, the divisor is the sum of absolute values:
||x||₁ = Σᵢ |xᵢ|
The sign of a component must not reduce the norm contributed by another component.
Minimal counterexample
For axis=0, p=1, and float32 input [1, -1]:
ONNX ReferenceEvaluator [ 0.0, 0.0]
ONNX Runtime CPU [ 0.5, -0.5]
exact x / Σ|x| [ 0.5, -0.5]
The exact L1 norm is |1| + |-1| = 2. The reference implementation instead forms the signed sum 1 + (-1) = 0; its zero-norm guard then replaces the result with a zero vector.
Two further cases isolate the same cause:
input [-1,-2] reference [ 1/3, 2/3] exact [-1/3, -2/3]
input [ 1,-3] reference [-1/2, 3/2] exact [ 1/4, -3/4]
The second reference output even has L1 norm 2, so it is not normalized.
Cause
The current implementation computes:
norm = np.power(np.power(x, p).sum(axis=axis), 1.0 / p)
For p=2, squaring removes the sign. For p=1, it does not. The definition requires np.abs(x) before exponentiation.
The existing p=1 backend examples use only non-negative inputs, so signed summation and absolute summation happen to agree in those tests.
Independent verification
- Exact arithmetic gives
[1/2, -1/2]for the minimal input. - NumPy
x / np.sum(np.abs(x))gives[0.5, -0.5]in float32. - ONNX Runtime 1.29.0 returns the same result on the CPU provider.
- ONNX ReferenceEvaluator 1.22.0 returns
[0, 0]. - The formula remained present on ONNX
maincommit1fdd92cf2f70f7a00c55d9153d243829d9349a96, checked 2026-09-07. - Searches across open and closed ONNX issues and pull requests using four relevant phrasings found no duplicate.
The executable reproducer is published at gero-onnx-reference-lpnormalization-audit.
Impact and boundary
This defect affects the Python ReferenceEvaluator when p=1 and the reduced axis contains negative values. It does not implicate ONNX Runtime, which matched the exact result in every tested case. The p=2 path is not implicated.
A reference evaluator is used as an oracle by backend authors and conformance tests. Here, a correct runtime can disagree with the official reference, and a consumer of onnx.reference can receive a vector with wrong signs, magnitudes, or normalization.
This is an ordinary numerical-correctness defect, not a security finding. No deployed-system impact or loss is claimed.
Proposed correction
Compute the norm from absolute values:
norm = np.power(np.power(np.abs(x), p).sum(axis=axis), 1.0 / p)
A regression test must include a negative p=1 input; [1, -1] distinguishes the two formulas with an exact result.
Upstream status
The one-line correction and a negative-input backend regression test were submitted as ONNX pull request #8427.